LAQUAtwin NA-11, Sodium Ion (Na+) Pocket Meter with plastic carry-case, 14 ml buffer standard solutions, 2x CR2032 batteries, dropper | Each (3200689159)
Key features
- Only pocket meter that directly measures sodium ion (Na⁺) concentration from a single drop of sample (≥0.05 ml with sampling sheet B)
- The only pocket meter that directly measures sodium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
- Minimum sample volume: 0.3ml (0.05ml with sampling sheet B)
- Up to 2 calibration points
- Auto standard recognition: 150 & 2000ppm sodium (default)
- Changeable high and low calibration values
Overview
The only pocket meter that directly measures sodium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
Specifications
| Model | NA-11 |
|---|---|
| Measurement principle | Ion selective electrode |
| Minimum sample volume | 0.3 mL (0.05 mL with sampling sheet B) |
| Measurement range | 2 to 9900 ppm (mg/L); 0.1 to 430 mmol/L |
| Resolution | 1 ppm (0 to 99 ppm); 10 ppm (100 to 990 ppm); 100 ppm (1000 to 9900 ppm) |
| Accuracy | ± 10% of actual value |
| Calibration points | Up to 2 |
| Temperature display range | 0 to 50.0 °C |
| Temperature calibration range | 5 to 40.0 °C |
| Display | Custom (monochrome) digital LCD with backlight |
| Operating temperature | 5 to 40.0 °C |
| Operating humidity | 85% or less relative humidity (no condensation) |
| Power | 2 × CR2032 batteries |
| Battery life | Approx. 400 hours continuous use without backlight |
| Material | ABS epoxy |
| Dimensions | 164 × 29 × 20 mm (excluding projections) |
| Weight | Approx. 50 g (excluding batteries) |
| Waterproof rating | IP67 dust/waterproof |
| Functions | Auto standard recognition, Changeable high and low calibration values, Multiplication compensation, Temperature calibration, Auto hold / auto stable measurement, Switchable backlight, Automatic power off (30 min), Low battery indicator, Replaceable sensor |
Applications
Used for direct measurement of sodium ion concentration in plant sap, soil extracts, irrigation water, food and beverage samples, saliva, sweat and biological fluids. Common applications include agricultural nutrient monitoring, hydroponics, low-sodium food QA, and environmental water screening.
Setup guide
- Insert 2 × CR2032 batteries into the meter (battery compartment on the back).
- Remove the sensor cap and apply a few drops of the 150 ppm standard onto the flat sensor; press the calibration key and wait for the meter to auto-recognise the standard.
- Rinse the sensor with DI water, then apply the 2000 ppm standard and repeat the calibration.
- Rinse again, then apply 0.05-0.3 ml of the sample (use sampling sheet B for 0.05 ml volumes).
- Wait for the auto-stable indicator and read the concentration in ppm.
Compatibility
HORIBA LAQUAtwin 4M Kit (1300083234); HORIBA sodium standard solutions (150 ppm and 2000 ppm, 14 ml bottles); HORIBA sampling sheet B (Y046); CR2032 batteries; HORIBA rinse bottle (60 ml).
Precautions
Handle the flat sensor carefully — do not scratch the ion-selective membrane with sharp or abrasive objects. Always rinse the sensor with DI water after measuring corrosive or high-ionic-strength samples. Replace the sensor cap when not in use to prevent dehydration of the membrane. Use only HORIBA-recommended standard solutions for calibration.
FAQ
How does the LAQUAtwin NA-11 measure sodium from a single drop?
The NA-11 uses a flat ion-selective electrode sensor, so a few drops (minimum 0.3 mL, or 0.05 mL with sampling sheet B) placed on the sensor are enough. The same flat sensor also handles viscous liquids, solids and powders, and no beaker is needed. The range is 2 to 9900 ppm (0.1 to 430 mmol/L).
How do I calibrate the NA-11 and which standards does it use?
Calibrate with two points, by default the 150 ppm and 2000 ppm sodium standards, which the meter recognises automatically. Rinse and dry the sensor, cover it with standard, close the cover, press CAL, and repeat for the second point. Calibration is stored when the meter is switched off, and the calibration values can be changed.
Which ions or pH conditions affect NA-11 sodium readings?
HORIBA lists potassium and rubidium ions as interfering, each with a selectivity coefficient of 1 x 10 to the minus 2 relative to sodium, and states a working pH of 3 to 9. Particles in samples such as soil extracts can also disturb readings, so use sampling sheet B with the sheet holder for those.
How do I replace and store the NA-11 sensor?
The sensor is a replaceable consumable part; HORIBA lists sensor S022 (article 3200459867) for the NA-11. Rinse it after use, dab it dry, close the cover and store at room temperature. It can be stored dry, but condition it with a few drops of 2000 ppm standard for a few hours after long disuse, then recalibrate.
What accuracy, waterproofing and battery life does the NA-11 have?
Accuracy is plus or minus 10 percent of the actual value. The body is rated IP67 for dust and water, and the meter runs on two CR2032 batteries for about 400 hours of continuous use without backlight.