Toppette ingle-channel Adjustable Volume 2-20μl (Metal Nozzle) | Each (7030141005)Price on request
SKU: 7030141005Brand: DLab Scientific

Toppette ingle-channel Adjustable Volume 2-20μl (Metal Nozzle) | Each (7030141005)

Key features

  • 2-20 μL volume range with metal nozzle for superior chemical resistance
  • Metal nozzle resists abrasion from repeated tip mounting
  • Ergonomic lightweight body; digital display; calibration adjusted with the DLab calibration tool
  • Compatible with universal 200 μL tips
  • ISO 8655 compliant with individual test certificate
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The DLab TopPette 2-20 μL with metal nozzle is a single-channel adjustable-volume mechanical pipette for low-volume precision work. The metal (stainless steel) nozzle offers superior durability vs plastic nozzles, especially when tips are mounted repeatedly or when aggressive solvents are used.

Specifications

ModelTopPette Metal Nozzle (Cat. No. 7030141005)
BrandDLab Scientific (Beijing)
TypeSingle-channel, adjustable volume, air displacement
Volume Range2-20 μL
Increment (Step)0.1 μL (fine adjustment)
Accuracy (±%)±2.5% at 2 μL; ±1.5% at 10 μL; ±1.0% at 20 μL
Precision (CV%)≤1.5% at 2 μL; ≤0.5% at 10 μL; ≤0.4% at 20 μL
Tip Cone MaterialStainless steel (metal nozzle)
Tip Cone ColorWhite / natural metal
DisplayDigital mechanical counter
CalibrationAdjusted with the DLab calibration tool; refer to ISO 8655
AutoclavabilityLower shaft only (121°C)
Weight~80 g
Length180 mm
StandardISO 8655; CE-marked

Applications

Used in molecular biology (PCR setup, qPCR, DNA quantification), drug discovery, and analytical chemistry requiring low-volume (2-20 μL) precision. The metal nozzle is preferred for high-throughput environments with frequent tip changes.

Setup guide

  1. Set volume via thumb wheel; verify on display.
  2. Attach tip firmly to metal nozzle; pre-wet 3 times.
  3. Press plunger to first stop; immerse tip just below the surface, no deeper than 2 mm.
  4. Slowly release plunger; wait 1 second.
  5. Dispense to first stop, then second stop to blow out.

Compatibility

Compatible with universal 200 μL pipette tips. Optional: replacement seal kit; calibration tool; pipette stand.

Precautions

Never pipette without a tip. Do not invert pipette with liquid in tip. Always pre-wet tip 3 times. Metal nozzle may corrode with prolonged exposure to strong acids/bases — rinse after use.

Documents

FAQ

Can the TopPette 2-20 µL pipette be autoclaved?

DLab's pipette guide classes TopPette pipettes as semi-autoclavable: only the lower section can be autoclaved, at 121 C and 1 bar for 20 minutes. Let it cool and dry for 12 hours before use and check its performance afterwards. MicroPette Plus is the fully autoclavable DLab series.

How do I pipette correctly with the TopPette metal nozzle 2-20 µL?

Fit the tip firmly on the nozzle, set the volume within range approaching from above, and pre-wet the tip 2-3 times. DLab's guide gives a maximum immersion depth of 2 mm for this volume class, so keep the tip just below the meniscus and hold the pipette vertical while aspirating.

How do I check or adjust the calibration of the TopPette 2-20 µL pipette?

To check volume, weigh dispensed distilled water on an analytical balance and convert the mass to volume with the ISO 8655-6 Z factor for the water temperature and pressure; 1 mL does not weigh exactly 1 g. To adjust, DLab's guide says to turn the calibration adjustment lock with the calibration tool. DLab states its specifications are guidelines and user calibration should refer to ISO 8655.

How should I store the 2-20 µL pipette and check it for leaks?

After use set the volume to the top of the range so the spring relaxes, and keep the pipette upright on a hook or pipette rack. Never lay it down with liquid in the tip. For a leak check, aspirate liquid, hold the pipette vertical for a few seconds and see if the level drops; if it does, check the tip fit, the spring and the piston.

When should I use reverse pipetting with the 2-20 µL pipette?

Use forward pipetting for aqueous, low-density liquids. DLab recommends reverse pipetting for viscous or volatile liquids: press to the second stop, release to aspirate more than the set volume, dispense to the first stop and discard the excess left in the tip. Pre-wet the tip by pipetting the liquid 2-3 times when you change volume or tip.