pH 4,01 buffer solution, 500 ml, accuracy ± 0,01 @ 25°C * | 500ml / Bottle (1300045602)Price on request
SKU: 1300045602Brand: HORIBA

pH 4,01 buffer solution, 500 ml, accuracy ± 0,01 @ 25°C * | 500ml / Bottle (1300045602)

Key features

  • NIST-traceable pH 4.01 buffer standard, accuracy ±0.01 @ 25°C
  • Supplied in a 500 ml dosing bottle for convenient, drip-free dispensing
  • Comes with a certificate of analysis for full metrological traceability
  • Coloured red per HORIBA convention for instant visual identification as pH 4 buffer
  • Compatible with HORIBA and other pH meters and electrodes that recognise a pH 4.01 buffer
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

HORIBA pH 4.01 (±0.01 at 25°C) buffer solution is a NIST-traceable primary calibration standard supplied in a 500 ml dosing bottle with certificate of analysis. It is coloured red for easy identification and used to calibrate the acidic end of any pH electrode that supports USA or NIST buffer sets.

Specifications

Article number1300045602
ProductpH 4.01 Buffer Solution
pH value @ 25°C4.01 ±0.01
Volume500 ml
PackagingDosing bottle with dropper cap
TraceabilityNIST-traceable, supplied with certificate
Temperature reference25 °C
ColourRed (HORIBA colour convention)
Shelf life2 years sealed, expiry date on bottle label
Storage5-30 °C, tightly closed, away from direct sunlight
BrandHORIBA Advanced Techno, Co., Ltd.

Applications

Used as the low-point (acidic) calibration standard for HORIBA and third-party pH meters and electrodes that use USA or NIST pH buffer sets. Typical applications include laboratory, field, environmental, food, and water-quality pH measurements where two- or three-point calibration is required.

Setup guide

  1. Dispense a few drops of fresh pH 4.01 buffer onto the electrode (or into a clean beaker).
  2. Immerse the pH electrode and start calibration.
  3. Wait for the reading to stabilise and confirm the pH 4.01 calibration point.
  4. Rinse the electrode thoroughly with DI water before moving to the next buffer (e.g. pH 7.00).
  5. Discard used buffer — never return it to the bottle.

Compatibility

HORIBA LAQUAtwin pH-11/22/33 pocket meters; HORIBA LAQUA PH200/PH220/PH1100/PH1200/PH1300/PH1500/PH2000 series; HORIBA twin pH B-71X series; any pH meter that recognises USA or NIST pH buffer sets at pH 4.01.

Precautions

For calibration use only; do not ingest. Avoid contact with skin and eyes — rinse with water if spilled. Recap the bottle immediately after dispensing to prevent CO₂ absorption and contamination, which will drift the pH value.

FAQ

Is the HORIBA 4.01 500 ml buffer traceable and does it come with a certificate?

HORIBA states that its LAQUA buffers and standard solutions in dosing bottles are traceable to NIST standard reference materials and that each solution is supplied with a certificate of analysis. The lot number on the bottle links the solution to its traceability record.

How long does the pH 4.01 buffer last, unopened and after opening?

HORIBA gives a 2 year shelf life for sealed LAQUA dosing bottles stored as instructed, with the expiry date on the label. After opening, only a small amount of air gets into the bottle, so usable life is extended. Carbon dioxide in air can contaminate standards, so recap right after use.

Why is this buffer supplied in a dosing bottle and can I pour leftover back?

The dosing bottle delivers solution through a side straw into a separate calibration chamber, so used solution never returns to the bottle. Never pour used buffer back, because contamination shifts the value and spoils later calibrations. Discard the solution left in the chamber after each calibration.

What is the pH 4.01 buffer used for and where do I find its temperature table?

It is the acidic calibration point for pH electrodes and meters, normally used together with pH 7.00 for a two-point calibration, or with pH 7.00 and 10.01 for three points. The nominal value applies at 25 C; the bottle label carries a temperature table, so check the value at your actual buffer temperature if the meter does not compensate automatically.

Which meters can I use the pH 4.01 500 ml buffer with?

It suits any pH meter or electrode that recognises a 4.01 buffer, including HORIBA LAQUAtwin pocket meters and LAQUA bench or handheld meters. The 500 ml size is suited to benches with regular calibration; for single-drop use on a LAQUAtwin flat sensor, the 14 ml dropper bottles are the smaller alternative.