-40℃, Biomedical Freezer, Capacity 90 L, single door, drawers, USB port, remote alarm contact | Each (MDF-40U90)Price on request
SKU: MDF-40U90Brand: Antech Scientific

-40℃, Biomedical Freezer, Capacity 90 L, single door, drawers, USB port, remote alarm contact | Each (MDF-40U90)

Key features

  • Microprocessor-controlled -40°C biomedical freezer for reliable sample storage
  • 90 L capacity with internal drawers for organised sample access
  • USB port for data download (temperature history)
  • Remote alarm contact for building monitoring integration
  • Single door with key lock; CFC-free urethane insulation
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The Antech Scientific MDF-40U90 is a -40°C biomedical freezer with 90 L capacity, designed for storage of biological samples (reagents, enzymes, samples) requiring sub-zero temperatures. The unit features microprocessor-controlled temperature, USB data logging, remote alarm contacts, and a lockable single door with internal drawers.

Specifications

ModelMDF-40U90
BrandAntech Scientific
TypeBiomedical freezer, single door
Temperature Range-40°C class (check the nameplate for the settable range)
Capacity90 L net
Cooling SystemDirect cooling, CFC-free refrigerant
CompressorHermetically sealed
InsulationCFC-free rigid urethane foam
Drawers2-3 (typically) with transparent fronts
External Dimensions (W x D x H)~540 x 600 x 850 mm (typical)
Internal Dimensions~440 x 410 x 500 mm (approx)
Weight~70 kg
Power220-240V, 50 Hz
Power Consumption~120 W (typical)
AlarmAudible + visual high/low temp, door ajar, power failure
Remote Alarm ContactYes (voltage-free contact)
Data OutputUSB port for temperature download
DoorSingle, lockable, magnetic gasket
DefrostManual

Applications

Used in clinical labs, research labs, biobanks, and pharmaceutical storage for reagents, enzymes, antibodies, DNA/RNA, biological samples, vaccines requiring -40°C storage. Suitable for low-volume applications or as a secondary backup freezer.

Setup guide

  1. Place unit on level floor; allow 4 hours for refrigerant to settle after transport.
  2. Connect power; set target temperature to -40°C via control panel.
  3. Allow 24 hours for temperature stabilization.
  4. Pre-cool samples before loading; load samples into drawers (max 70% capacity).
  5. Connect USB cable for data download; verify alarm contacts work via test.

Compatibility

Includes: freezer unit, 2-3 drawers, instruction manual, USB cable for data export. Optional: temperature data logger; remote alarm panel; CO2/LN2 backup cooling system; chart recorder.

Precautions

Do not store volatile or flammable materials — not explosion-proof. Allow 24 hours stabilization after installation before loading samples. Do not exceed 70% capacity — overloading impairs air circulation. Connect to backup power (UPS) for critical samples; alarm sounds but samples may thaw on power loss.

FAQ

What is the Antech Scientific MDF-40U90 freezer used for?

It is described as a -40 C biomedical freezer for reagents, enzymes and other samples that need a deeper freeze than a standard -20 C freezer but not ultra-low storage. Check the manual or nameplate for the exact settable temperature range and capacity before relying on the listed figures.

How should I load the MDF-40U90 freezer?

Pre-cool samples before loading, add them gradually rather than all at once, and leave small gaps between boxes. Keep door openings short, because each opening lets warm, humid air in and the freezer must then recover.

Does the MDF-40U90 need defrosting?

Manual-defrost freezers build up frost over time, and this model is listed as manual defrost. Defrost when the frost layer becomes thick: move contents to another freezer first, then wipe the cabinet dry and let it reach set temperature before reloading.

What alarm and monitoring options does the MDF-40U90 offer?

The listing describes audible and visual temperature alarms, a USB port for temperature history and a voltage-free remote alarm contact for a building monitoring system. Confirm these functions in the manual, and test the alarm after installation and after any power outage.

Is the MDF-40U90 safe for flammable or volatile materials?

No. It is a standard biomedical freezer, not explosion-proof, so do not store volatile solvents or flammable chemicals in it.