TopPette Adjustable Volume Mechanical Pipettes 50-200μL | Each (7010101011)Price on request
SKU: 7010101011Brand: DLab Scientific

TopPette Adjustable Volume Mechanical Pipettes 50-200μL | Each (7010101011)

Key features

  • 50-200 μL narrow-range pipette for high-precision applications
  • Reduced volume range gives better accuracy at upper end vs full 20-200 μL pipette
  • Ergonomic lightweight body; digital display; calibration adjusted with the DLab calibration tool
  • Universal yellow tip cone fits standard 200 μL tips
  • ISO 8655 compliant with individual test certificate
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The DLab TopPette 50-200 μL is a narrow-range single-channel adjustable pipette designed for applications requiring higher precision in the 50-200 μL range. The narrow range improves accuracy vs full-range 20-200 μL pipettes. Same ergonomic body, digital display, and calibration with the DLab calibration tool as standard TopPette models.

Specifications

ModelTopPette (Cat. No. 7010101011)
BrandDLab Scientific (Beijing)
TypeSingle-channel, adjustable volume, air displacement
Volume Range50-200 μL (narrow range for higher precision)
Increment (Step)1 μL
Accuracy (±%)±1.5% at 50 μL; ±0.8% at 100 μL; ±0.8% at 200 μL
Precision (CV%)≤0.6% at 50 μL; ≤0.3% at 100 μL; ≤0.3% at 200 μL
Tip Cone ColorYellow
DisplayDigital mechanical counter
CalibrationAdjusted with the DLab calibration tool; refer to ISO 8655
AutoclavabilityLower shaft only (121°C)
Weight~80 g
Length180 mm
StandardISO 8655; CE-marked

Applications

Used in clinical chemistry, hematology, microbiology, and QC labs where repeat dispensing of 50-200 μL volumes is required with high precision. Common in assay development, validation, and transfer protocols.

Setup guide

  1. Set volume via thumb wheel; verify on display.
  2. Attach tip firmly; pre-wet 3 times.
  3. Press plunger to first stop; immerse tip just below the surface (see the pipette user guide for the maximum depth).
  4. Slowly release plunger; wait 1 second.
  5. Dispense to first stop, then second stop to blow out.

Compatibility

Compatible with universal 200 μL pipette tips. Optional: replacement seal kit; calibration tool; wall stand.

Precautions

Never pipette without a tip. Do not invert pipette with liquid in tip. Always pre-wet tip 3 times. Use only within calibrated range — do not force below 50 μL.

Documents

FAQ

Can the TopPette 50-200 µL pipette be autoclaved?

DLab's pipette guide classes TopPette pipettes as semi-autoclavable: only the lower section can be autoclaved, at 121 C and 1 bar for 20 minutes. Let it cool and dry for 12 hours before use and check its performance afterwards. MicroPette Plus is the fully autoclavable DLab series.

How do I pipette correctly with the TopPette 50-200 µL?

Set the volume within the range only, approaching it from above, as forcing the knob past the limit can jam the mechanism. Pre-wet a tight-fitting tip 2-3 times. Keep the tip just below the meniscus, hold the pipette vertical, press smoothly to the first stop and release slowly, because fast aspiration creates bubbles that block the tip.

How do I check or adjust the calibration of the TopPette 50-200 µL pipette?

To check volume, weigh dispensed distilled water on an analytical balance and convert the mass to volume with the ISO 8655-6 Z factor for the water temperature and pressure; 1 mL does not weigh exactly 1 g. To adjust, DLab's guide says to turn the calibration adjustment lock with the calibration tool. DLab states its specifications are guidelines and user calibration should refer to ISO 8655.

How should I store the 50-200 µL pipette and check it for leaks?

After use set the volume to the top of the range so the spring relaxes, and keep the pipette upright on a hook or pipette rack. Never lay it down with liquid in the tip. For a leak check, aspirate liquid, hold the pipette vertical for a few seconds and see if the level drops; if it does, check the tip fit, the spring and the piston.

When should I use reverse pipetting with the 50-200 µL pipette?

Use forward pipetting for aqueous, low-density liquids. DLab recommends reverse pipetting for viscous or volatile liquids: press to the second stop, release to aspirate more than the set volume, dispense to the first stop and discard the excess left in the tip. Pre-wet the tip by pipetting the liquid 2-3 times when you change volume or tip.