SCT-EC-MAXI-HR conductivity maxi controller, high range 0-350,000 µS/cm (SCT-108.005.19)
Key features
- Three EC ranges can be set in one controller and switched easily
- Supplied with a suitable electrode on SCT standard 10 m cable (new series)
- Large, clear blue-white LCD display
- Microprocessor based for stable, accurate readings
- Low power consumption and low internal heat
- Isolated 4-20 mA current output
Overview
The SCT-108.005.19 is a microprocessor-based, panel-mounted high-range electrical conductivity controller for online analysis and monitoring in water applications. It has a large LCD, isolated 4-20 mA output and high/low limit relay contacts, and three EC ranges can be set and switched in one controller. It is supplied with a suitable electrode on SCT standard cable.
Specifications
| Product no | SCT-108.005.19 |
|---|---|
| Model no | SCT-EC-MAXI-HR |
| Display method | Liquid-crystal display with 3½ bit LCD segment code |
| Accuracy | 1.5% (FS) |
| Stability | ±2×10-3 (FS)/24h |
| Work pressure | 0~0.5 MPa |
| Media temperature | 0~50 °C |
| Temperature compensation | With 25 °C as the reference point, digital compensation |
| Output current | Isolation of 4~20 mA active output |
| Control output | Double contacts output of high limit (normally open) & low limit (normally closed) |
| Contact capacity | 7A/250C ac (with resistance load) |
| Environment conditions | Temperature: 0~50 °C; humidity: ≤85% RH |
| Power supply | AC 220 V ±10% 50 Hz |
| Overall dimension | 96×96×120 mm (height x width x depth) |
| Face opening | 92×92 mm |
| Installation method | Panel-mounted |
| Weight | 1.5 kg |
Applications
Inline measurement and control of electrical conductivity in water-related applications.
In the box
- Conductivity controller
- Conductivity electrode with SCT standard 10 m cable (per source text)
Documents
FAQ
What is the range of the SCT-EC-MAXI-HR SCT-108.005.19?
SCT-108.005.19 is listed as a high-range SCT-EC-MAXI-HR, and its product name gives 0-350,000 uS/cm (350 mS/cm), but the listing has no specification table, so confirm the range with SCT. It has a large LCD, an isolated 4-20 mA output and high and low limit relay contacts, and three EC ranges can be set and switched.
Why is a different electrode needed for very high conductivity?
The suitable cell constant rises with conductivity: low-conductivity water needs a small K, while strong solutions need a larger one so the current stays measurable. SCT supplies a suitable electrode on its 10 m standard cable with this model, so keep that electrode with the controller.
How should I care for the electrode in brine?
Rinse the cell with deionised water after use. Oily films can be removed with a water-miscible solvent such as ethanol, then rinsed. Solid build-up can be wiped off gently with a cotton bud soaked in detergent solution, then rinsed. Avoid abrasives and harsh chemicals, check the manual for the electrode material, and recalibrate afterwards. Brine can crystallise on the electrode when it dries, so keep it wet and rinse it with deionised water after shutdowns.
How do I use the relay contacts on the SCT-108.005.19?
The high-limit contact is normally open and the low-limit contact normally closed, each rated 7 A at 250 V AC resistive. Use the high limit to open a blowdown or discharge valve and the low limit for an alarm or dosing start, with an interposing relay for motors.
Which calibration standard should I use at these levels?
Use a standard in the upper part of your range, for example 12.88 mS/cm or a higher certified standard, because calibrating far below the working value reduces accuracy there. Rinse the cell, keep the standard at a known temperature and recalibrate after cleaning.