pH 10,01 buffer solution, 500 ml, accuracy ± 0,02 @ 25°C * | 500ml/ Bottle (1300045605)Price on request
SKU: 1300045605Brand: HORIBA

pH 10,01 buffer solution, 500 ml, accuracy ± 0,02 @ 25°C * | 500ml/ Bottle (1300045605)

Key features

  • NIST-traceable pH 10.01 buffer standard, accuracy ±0.02 @ 25°C
  • Supplied in a 500 ml dosing bottle for convenient, drip-free dispensing
  • Comes with a certificate of analysis for full metrological traceability
  • Coloured blue per HORIBA convention for instant visual identification as pH 10 buffer
  • Compatible with all HORIBA pH meters and electrodes (LAQUAtwin, LAQUA, twin series) and other brands that recognise USA/NIST pH buffers
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

HORIBA pH 10.01 (±0.02 at 25°C) buffer solution is a NIST-traceable alkaline calibration standard supplied in a 500 ml dosing bottle with certificate of analysis. It is coloured blue for easy identification and used to calibrate the alkaline end of any pH electrode that supports USA or NIST buffer sets. Alkaline buffers absorb CO₂ from air; recap immediately after use.

Specifications

Article number1300045605
ProductpH 10.01 Buffer Solution
pH value @ 25°C10.01 ±0.02
Volume500 ml
PackagingDosing bottle with dropper cap
TraceabilityNIST-traceable, supplied with certificate
Temperature reference25 °C
ColourBlue (HORIBA colour convention)
Shelf life2 years sealed, expiry date on bottle label (alkaline buffers are CO₂-sensitive)
Storage5-30 °C, tightly closed, away from direct sunlight
BrandHORIBA Advanced Techno, Co., Ltd.

Applications

Used as the high-point (alkaline) calibration standard for HORIBA and third-party pH meters and electrodes that use USA or NIST pH buffer sets. Common applications include laboratory, field, environmental, and water-quality pH measurements where three-point calibration spanning the full pH range is required.

Setup guide

  1. Dispense a few drops of fresh pH 10.01 buffer onto the electrode (or into a clean beaker).
  2. Immerse the pH electrode and start calibration.
  3. Wait for the reading to stabilise and confirm the pH 10.01 calibration point.
  4. Rinse the electrode thoroughly with DI water before use.
  5. Discard used buffer — never return it to the bottle.

Compatibility

HORIBA LAQUAtwin pH-11/22/33 pocket meters; HORIBA LAQUA PH200/PH220/PH1100/PH1200/PH1300/PH1500/PH2000 series; HORIBA twin pH B-71X series; any pH meter that recognises USA or NIST pH buffer sets at pH 10.01.

Precautions

For calibration use only; do not ingest. Avoid contact with skin and eyes. pH 10 buffer absorbs atmospheric CO₂ which slowly lowers the pH value — always recap the bottle immediately after dispensing and do not return used buffer to the bottle. Discard if the value drifts outside the stated accuracy.

FAQ

Is the HORIBA 10.01 500 ml buffer traceable and does it come with a certificate?

HORIBA states that its LAQUA buffers and standard solutions in dosing bottles are traceable to NIST standard reference materials and that each solution is supplied with a certificate of analysis. The lot number on the bottle links the solution to its traceability record.

How long does the pH 10.01 buffer last, unopened and after opening?

HORIBA gives a 2 year shelf life for sealed LAQUA dosing bottles stored as instructed, with the expiry date on the label. After opening, only a small amount of air gets into the bottle, so usable life is extended, but carbon dioxide in air can contaminate standards, especially pH 10.01 buffer. Recap immediately after use.

Why is this buffer supplied in a dosing bottle and can I pour leftover back?

The dosing bottle delivers solution through a side straw into a separate calibration chamber, so used solution never returns to the bottle. Never pour used buffer back, because contamination shifts the value and spoils later calibrations. Discard the solution left in the chamber after each calibration.

What is the pH 10.01 buffer used for and where do I find its temperature table?

It is the alkaline calibration point, used with pH 7.00 (and 4.01) when samples are above neutral. Calibrate with 7.00 first, then 10.01. The nominal value applies at 25 C; the bottle label carries a temperature table, so check the value at your actual buffer temperature if the meter does not compensate automatically.

Why does pH 10.01 buffer drift and how should I handle the 500 ml bottle?

Alkaline buffers absorb carbon dioxide from the air, which slowly lowers their pH. HORIBA names pH 10.01 as one of the solutions most affected by CO2. Keep the cap tight, dispense only what you need, never return used solution, and replace the bottle if calibration starts to fail.