Scichemtech
Categories33
Region · LanguageSA · English
United Arab Emirates

English

Saudi Arabia

English

Qatar

English

Oman

English

Kuwait

English

Bahrain

English

Middle East & North Africa

English

Türkiye

TürkçeEnglish

Kazakhstan

РусскийҚазақшаEnglish

Uzbekistan

O'zbekchaРусскийEnglish

+971 50 391 6126WhatsAppsales@sctme.ae
LAQUAtwin 4ECSalt-11 salinity pocket meter (3201077528)Price on request
SKU: 3201077528Brand: HORIBA

LAQUAtwin 4ECSalt-11 salinity pocket meter (3201077528)

Key features

  • Measures conductivity on a 0.12 ml sample and converts it to salinity or salt concentration
  • Salinity range 0.0 to 100.0 g/L (ppt) or 0.00 to 10.00%
  • NaCl or seawater salinity display unit (set in setup)
  • Up to 2-point auto calibration with recognition of 0.50% and 5.00% NaCl standards
  • ±2% full scale (0.0 to 9.9 g/L), ±4% full scale (10.0 to 100.0 g/L)
  • IP67 waterproof, temperature display 0 to 50.0 °C, about 400 hours battery life
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The LAQUAtwin 4ECSalt-11 is a pocket salinity meter that uses HORIBA's 4-electrode conductivity sensor and converts the reading to salinity or salt concentration. It measures from 0.12 ml of sample, covers 0 to 100 g/L, and can display NaCl or seawater salinity. It is supplied in a carrying case with 0.5% and 5.0% NaCl standards and conditioning solution.

Specifications

Product no3201077528
Model noLAQUAtwin 4ECSalt-11
Measurement principle4-electrode method
Minimum sample volume0.12 ml
Salinity range (g/L)0.0 to 100.0 g/L (ppt), 0.1 g/L resolution
Salinity range (%)0.00 to 10.00%, 0.01% resolution
Accuracy±2% FS (0.0 to 9.9 g/L), ±4% FS (10.0 to 100.0 g/L)
Calibration pointsUp to 2
Display unit (setup)NaCl, seawater
Auto standard recognition0.50% and 5.00% NaCl
Temperature display0 to 50.0 °C
Temperature adjustment5 to 40.0 °C
Temperature compensationAutomatic, 2%/°C fixed
DisplayCustom monochrome LCD with backlight
Operating conditions5 to 40 °C, 85% RH or less (no condensation)
ProtectionIP67 waterproof and dustproof
Power2 x CR2032 batteries (not included)
Battery lifeApprox. 400 hours continuous (backlight off)
MaterialABS epoxy body, carbon sensor
Dimensions164 x 29 x 20 mm (excluding projections)
WeightApprox. 45 g (meter only, without batteries)
Replacement sensorS074-4EC
Warranty2 years meter, 6 months sensor

Applications

Salt content of foods, brines and pickling solutions, seawater and aquaculture water, and soil or irrigation salinity checks.

Setup guide

  1. Fit 2 x CR2032 batteries (not included) and slide the sensor onto the meter, checking the waterproof gasket is clean and seated.
  2. Condition the sensor: place a few drops of conditioning solution on it, wait 20 minutes, then rinse with pure water.
  3. Choose NaCl or seawater as the display unit in setup to suit the sample.
  4. Calibrate with the 0.50% NaCl standard, then the 5.00% NaCl standard, rinsing between them.
  5. Place a few drops of sample on the sensor, close the cover and read when the stability indicator appears.
  6. Rinse the sensor with pure water and store the meter dry in its case, not immersed in water.

In the box

  • LAQUAtwin 4ECSalt-11 meter with replaceable 4-cell salt sensor
  • 5% NaCl standard (14 ml)
  • 0% NaCl standard (14 ml)
  • Conditioning solution (4 ml)
  • Dropper
  • Instruction manual and quick manual
  • Carrying case

Precautions

Do not measure organic solvents, oils, adhesives, cement, alcohols, surfactants, concentrated acids (pH 0-2) or concentrated alkalis (pH 12-14); rinse the sensor with pure water straight away after any contact. The meter is only waterproof with the sensor properly fitted, and its CR2032 coin cells (not included) are dangerous if swallowed.

FAQ

How do I calibrate the LAQUAtwin 4ECSalt-11 and which standards does it use?

Use the supplied NaCl standards, 5 ppt (0.5 percent) and 50 ppt (5 percent), for a 2-point calibration. Fill the measurement cell with standard without air bubbles, close the cover, wait about one minute until the reading stabilises, then press CAL. Rinse with pure water between points. Calibrate after conditioning the sensor.

Can the 4ECSalt-11 show seawater salinity as well as NaCl salinity?

Yes. A unit setting in setup lets the display show NaCl salinity or seawater salinity, in ppt or percent. HORIBA lists the range as 0.0 to 100.0 ppt (0.00 to 10.00 percent), where ppt means parts per thousand, equal to g/L. Listed accuracy is plus or minus 2 percent of full scale up to 9.9 ppt and 4 percent from 10.0 to 100.0 ppt.

How do I take a salinity reading with the 4ECSalt-11 and what are the AS and AH modes?

Drop the sample into the measurement cell up to the rim with no air bubbles, close the protection cover and wait about one minute. In Auto Stable (AS) mode the value locks when stable. In Auto Hold (AH) mode the live value shows until you press MEAS, then it locks when stable. Press MEAS again to release it.

How should the 4ECSalt-11 be stored and what can damage its sensor?

Rinse the sensor with pure water, then store the meter with the sensor attached in its case at 5 to 40 C, 85 percent humidity or less, away from sunlight. Do not store it immersed in water. Avoid organic solvents, oils, adhesives, cement, alcohols, surfactants, concentrated acids and alkalis, which can damage the sensor.

Which replacement sensor does the 4ECSalt-11 use, and is it the same as the Salt-11 sensor?

It uses the S074-4EC salt sensor, part number 3201079163. This is not compatible with the older Salt-11, which uses the S071 sensor. The meter and sensor should both be printed Salt EC 4-cell. After replacing the sensor, initialise the calibration data and recalibrate.