MicroPette Plus Single-channel Fully Autoclavable Adjustable Volume Mechanical Pipette 10-100μl | Each (7030301008)Price on request
SKU: 7030301008Brand: DLab Scientific

MicroPette Plus Single-channel Fully Autoclavable Adjustable Volume Mechanical Pipette 10-100μl | Each (7030301008)

Key features

  • Fully autoclavable at 121°C for sterile molecular biology work
  • 10-100 μL volume range — common PCR and ELISA range
  • Ergonomic lightweight body; digital display; calibration adjusted with the DLab calibration tool
  • ISO 9001 / ISO 13485 certified manufacturing
  • ISO 8655 individual test certificate
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The DLab MicroPette Plus 10-100 μL is a fully autoclavable single-channel adjustable mechanical pipette covering the commonly used 10-100 μL range. Designed for molecular biology and clinical labs where sterility between samples is required.

Specifications

ModelMicroPette Plus (Cat. No. 7030301008)
BrandDLab Scientific (Beijing)
TypeSingle-channel, adjustable volume, air displacement, fully autoclavable
Volume Range10-100 μL
Increment (Step)1 μL
Accuracy (±%)±3.0% at 10 μL; ±1.0% at 50 μL; ±0.8% at 100 μL
Precision (CV%)≤1.5% at 10 μL; ≤0.4% at 50 μL; ≤0.15% at 100 μL
Tip Cone ColorYellow
AutoclavabilityFully autoclavable (121°C / 1 bar / 20 min)
DisplayDigital mechanical counter
CalibrationAdjusted with the DLab calibration tool; refer to ISO 8655
QualityISO 9001 / ISO 13485 certified
Weight~80 g
Length180 mm
StandardISO 8655; CE-marked

Applications

Used in molecular biology (PCR, qPCR), immunoassays (ELISA), cell culture, and clinical diagnostics where sterile pipetting of 10-100 μL volumes is required. Common in labs working with bacteria, viruses, or RNase-sensitive samples.

Setup guide

  1. After autoclaving, allow to cool and dry for 12 hours.
  2. Set volume; attach tip; pre-wet 3 times.
  3. Press to first stop; immerse tip just below the surface, no deeper than 2 mm.
  4. Aspirate; wait 1 second.
  5. Dispense to first stop then second stop.

Compatibility

Compatible with universal 200 μL pipette tips. Optional: replacement seal kit; calibration tool; wall stand.

Precautions

Cool to room temperature after autoclaving. Do not autoclave more than 20 minutes. Check performance after every autoclave cycle and grease the piston and seal after every 10th.

Documents

FAQ

Is the MicroPette Plus 10-100 µL pipette fully autoclavable?

Yes. DLab states MicroPette Plus pipettes are fully autoclavable at 121 C and 1 bar for 20 minutes. Afterwards let the pipette cool and dry for 12 hours, check its performance, and grease the piston and seal after every 10 autoclave cycles.

What accuracy does the 10-100 µL MicroPette Plus achieve?

DLab's ISO 8655-2 error limits for this range are ±0.80% accuracy and 0.15% CV at 100 µL, and ±3.00% accuracy with 1.50% CV at 10 µL. DLab notes these are guidelines and user calibration should follow ISO 8655.

How do I check or adjust the calibration of the MicroPette Plus 10-100 µL pipette?

To check volume, weigh dispensed distilled water on an analytical balance and convert the mass to volume with the ISO 8655-6 Z factor for the water temperature and pressure. To adjust, turn the calibration adjustment lock with the calibration tool. DLab says each MicroPette Plus ships with an individual ISO 8655 calibration certificate and lists online calibration as available.

How do I pipette accurately with the 10-100 µL MicroPette Plus?

Fit a tight, DLab original tip, set the volume by turning the knob down to the value (approach from above, never past the range limit) and pre-wet the tip 2-3 times. DLab's guide gives a maximum immersion depth of 2 mm for this volume class, so keep the tip just below the meniscus and hold the pipette vertical while aspirating.

How should I store the 10-100 µL pipette and check it for leaks?

After use set the volume to the top of the range so the spring relaxes, and keep the pipette upright on a hook or pipette rack. Never lay it down with liquid in the tip. For a leak check, aspirate liquid, hold the pipette vertical for a few seconds and see if the level drops; if it does, check the tip fit, the spring and the piston.