Liquid Nitrogen Tank with Monitoring System | Each (Cryomajor47/127TL)Price on request
SKU: Cryomajor47/127TL

Liquid Nitrogen Tank with Monitoring System | Each (Cryomajor47/127TL)

Key features

  • 47 L liquid nitrogen storage capacity with 127 mm neck diameter for high sample throughput
  • 6 canisters (double level) accommodate up to 3,780 vials (2 mL) — large cryostorage capacity
  • Built-in monitoring system (TL variant) with low-LN2 alarm and temperature display
  • High vacuum + multilayer insulation for low static evaporation (~0.45 L/day)
  • Roller base optional for mobility; lockable lid for security
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The Cryomajor 47/127TL is a 47-liter liquid nitrogen storage tank with 127 mm neck diameter, 6 canisters, and an integrated LN2 level monitoring system (TL = Telemetry/Logging). It is designed for long-term cryogenic storage of biological samples (cells, embryos, sperm, vaccines) with high sample capacity and active monitoring for sample safety.

Specifications

ModelCryomajor 47/127TL
BrandCryomajor / equivalent to YDS-47-127-FS
TypeStatic LN2 storage tank (Dewar) with monitoring
Liquid N2 Capacity47 L
Neck Diameter127 mm
Number of Canisters6 (double level)
Vial Capacity~3,780 x 2 mL cryovials (typical)
Empty Weight~25.7 kg
Static Evaporation Rate~0.45 L/day
Static Holding Time~100 days
Outer Diameter508 mm
Height700 mm (overall)
Monitoring SystemDigital LN2 level + temperature display; low-level alarm
Alarm OutputAudible + remote alarm contacts
Power for Monitor220V AC (monitor only — tank itself is passive)

Applications

Used in IVF clinics, cell repositories, biobanks, vaccine research labs, and any facility requiring long-term cryogenic storage of biological samples. The 127 mm neck supports high-throughput sample retrieval. Monitoring system enables sample safety alerts in unmanned facilities.

Setup guide

  1. Place tank on level floor; ensure 1m clearance on all sides.
  2. Connect monitor to power; verify LN2 level sensor reads zero.
  3. Slowly pre-cool tank: add 5L LN2, wait 2 hours; repeat until full.
  4. Load canisters with samples (use cryo gloves + face shield).
  5. Set low-level alarm threshold (typically 10L); verify alarm triggers on test.

Compatibility

Includes: 6 canisters (double level), canister hangers, lid, monitoring system with display + alarm, instruction manual. Optional: roller base; lockable lid accessory; temperature data logger; auto-fill system; backup LN2 supply.

Precautions

Liquid nitrogen is -196°C — severe frostbite/cryogenic burn hazard; always wear cryo gloves and face shield when handling. Never seal the tank airtight — LN2 evaporation can cause pressure buildup. Use only in well-ventilated areas — asphyxiation hazard if N2 displaces oxygen. Monitor must be powered for alarm function — ensure backup power.

FAQ

How long does a liquid nitrogen tank like the Cryomajor 47/127TL hold LN2?

The listed static evaporation rate is about 0.45 L per day, and the listed static holding time is about 100 days for a full 47 L tank. In daily use with the lid opened often, real holding time is shorter, so check the level regularly.

What safety precautions apply when filling or opening the Cryomajor 47/127TL?

Liquid nitrogen is about -196 C, so wear cryogenic gloves, a face shield and closed clothing. Work in a well-ventilated room, because evaporated nitrogen displaces oxygen. Never seal the neck airtight.

How should I pre-cool and fill a new LN2 tank?

Fill slowly in small steps to avoid thermal shock to the inner vessel, let the tank cool, and top up gradually until full. Then load canisters and set the monitor low-level alarm.

What does the monitoring system do?

The listing describes a digital level and temperature display and a low-level alarm with audible and remote contacts on the TL variant. Confirm alarm behaviour in the manual. Because the monitor is mains powered per the listing, arrange backup power or a separate level check so an outage does not leave the tank unmonitored.

What samples can the 47/127TL store?

The tank is designed for long-term cryogenic storage of cells, embryos, sperm and similar biological samples in cryovials held in canisters. Keep an inventory so vials can be found quickly without leaving the lid open.