DPD100T Benchtop pH/DO Meter (Touch screen/Polarographic Type) | Each (4090010211)Price on request
SKU: 4090010211Brand: DLab Scientific

DPD100T Benchtop pH/DO Meter (Touch screen/Polarographic Type) | Each (4090010211)

Key features

  • 7-inch TFT color touch screen — intuitive operation and clear data viewing
  • Multi-parameter: pH, ORP, dissolved oxygen (DO), and temperature simultaneously
  • Polarographic DO probe with auto air pressure and salinity compensation
  • Up to 500-point data storage with USB export to PC
  • Auto calibration with auto buffer recognition for pH 4.01/7.00/10.01
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

The DLab DPD100T is a benchtop pH/DO meter with 7-inch touch screen, designed for multi-parameter measurement of pH, ORP, dissolved oxygen, and temperature. It uses a polarographic DO sensor and standard glass pH electrode. The meter supports auto calibration, 500-point data logging, and USB data export.

Specifications

ModelDPD100T
BrandDLab Scientific (Beijing)
Display7-inch TFT color touch screen
ParameterspH, ORP (mV), Dissolved Oxygen (mg/L & %), Temperature
pH Range-2.000 to 20.000 pH; Resolution 0.1/0.01/0.001 pH; Accuracy ±0.002 pH
ORP Range±2000 mV; Resolution 0.1 mV; Accuracy ±0.2 mV
DO Range0.00-20.00 mg/L (0-200% sat); Resolution 0.01 mg/L; Accuracy ±0.1 mg/L
Temperature Range0-105°C; Resolution 0.1°C; Accuracy ±0.2°C
CalibrationUp to 5-point pH; 2-point DO
DO Sensor TypePolarographic (Clark-type)
Data Storage500 readings with date/time stamp
OutputUSB (data export)
Power100-240V AC, 50/60 Hz
Dimensions200 x 240 x 85 mm (meter only)
Weight~1.5 kg

Applications

Used in environmental, biological, and pharmaceutical labs for monitoring DO and pH in cell culture, fermentation, water/wastewater analysis, aquaculture, and chemical oxygen demand (COD) sample preparation. Suitable for both routine QC and research applications requiring simultaneous multi-parameter monitoring.

Setup guide

  1. Connect pH electrode, DO probe, and ATC probe to meter.
  2. Power on; allow DO probe to polarize 5-10 minutes (DO reading stable).
  3. Calibrate pH: insert in pH 7.00 buffer, press CAL — meter auto-recognises; repeat for pH 4.01.
  4. Calibrate DO: insert probe in zero-oxygen solution (Na2SO3) then air-saturated water; press CAL.
  5. Rinse probes with DI water; immerse in sample; read pH + DO + temperature on touch screen.

Compatibility

Includes: pH electrode (combined glass, BNC connector), polarographic DO probe, ATC probe, electrode stand, USB cable, power adapter. Optional: data logging software; replacement DO membranes (DPD100T-MEM); pH electrode cleaning solutions.

Precautions

Polarographic DO probe requires 5-10 min polarization after power-on before first measurement. Keep DO membrane wet at all times — drying out damages membrane. pH electrode should be stored in 3M KCl solution; never store in distilled water. Calibrate daily for high-accuracy work.

Documents

FAQ

How long must the DPD100T polarographic DO probe polarise before measuring?

Polarographic (Clark-type) DO probes need a polarisation period after the meter is powered or the probe is connected, and the reading drifts until it is done. Follow the probe's instructions for the exact time and calibrate only once the DO reading is stable.

How do I calibrate pH and dissolved oxygen on the DPD100T?

The meter is specified for pH calibration of up to 5 points with automatic buffer recognition, and a 2-point dissolved oxygen calibration. For pH use fresh buffers, usually pH 7.00 first, then 4.01 and/or 10.01. For DO the two points are a zero-oxygen solution such as sodium sulfite and air-saturated water. Rinse the probes between steps and follow the on-screen prompts.

How should I care for the DO membrane and pH electrode on the DPD100T?

Keep the DO membrane clean and undamaged, keep the probe tip moist as the probe instructions advise, and replace the membrane if it is damaged or readings become unstable. Store the glass pH electrode in storage solution (commonly 3 M KCl), never in distilled water. Calibrate often, daily for high-accuracy work.

Which parameters and accessories does the DPD100T cover, and can data be exported?

The DPD100T measures pH, ORP (mV), dissolved oxygen (mg/L and % saturation) and temperature on a 7-inch colour touch screen. It stores 500 readings with date and time and exports them over USB. It ships with a pH electrode, DO probe, ATC temperature probe, electrode stand, USB cable and power adapter.

Does the DPD100T compensate for air pressure and salinity in DO readings?

Dissolved oxygen in mg/L depends on temperature, salinity and barometric pressure, so a meter has to account for them. The DPD100T is specified with air-pressure and salinity compensation plus temperature compensation from the ATC probe. Check the setup menu to see whether salinity must be entered for brackish samples.