1,413 uS/cm Calibration Solution, 500 ml | 500ml/ Bottle (1300045638)Price on request
SKU: 1300045638Brand: HORIBA

1,413 uS/cm Calibration Solution, 500 ml | 500ml/ Bottle (1300045638)

Key features

  • NIST-traceable 1,413 µS/cm (0.01 M KCl) conductivity calibration solution, ±1% accuracy
  • Supplied in a 500 ml dosing bottle for convenient, drip-free dispensing
  • Comes with a certificate of analysis for full metrological traceability
  • The universal mid-range conductivity reference recognised by all standard auto-recognition libraries
  • Compatible with all HORIBA conductivity cells (LAQUAtwin EC-11/22, LAQUA EC200/EC210/EC1100/EC1500/EC2000) and other brands
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

HORIBA 1,413 µS/cm (0.01 M KCl, ±1% at 25°C) Conductivity Calibration Solution is the international standard mid-range conductivity reference supplied in a 500 ml dosing bottle with certificate of analysis. It is used to calibrate conductivity cells for the bulk of routine water-quality and process measurements.

Specifications

Article number1300045638
ProductConductivity Standard Solution 500-EC-1413
Nominal value1,413 µS/cm at 25°C
Accuracy±1%
Composition0.01 M KCl aqueous solution
Volume500 ml
PackagingDosing bottle with dropper cap
TraceabilityNIST-traceable, supplied with certificate
Temperature reference25 °C
Shelf life2 years sealed, expiry date on bottle label
Storage5-30 °C, tightly closed, away from direct sunlight
BrandHORIBA Advanced Techno, Co., Ltd.

Applications

Used as the standard mid-range conductivity calibration point for HORIBA conductivity cells and electrodes in routine laboratory, environmental, food, and industrial water testing. Suitable for any application where sample conductivity falls between approximately 200 µS/cm and 2 mS/cm, including tap water, aquarium water, hydroponic nutrient solutions and most natural waters.

Setup guide

  1. Dispense a small amount of fresh 1,413 µS/cm standard into a clean, dry beaker (or apply a few drops onto the LAQUAtwin flat sensor).
  2. Immerse the conductivity cell and start calibration — most HORIBA meters auto-recognise 1,413 µS/cm.
  3. Wait for the reading to stabilise and confirm the calibration point.
  4. Rinse the cell thoroughly with DI water before measuring samples or moving to the next standard.
  5. Discard used standard — never return it to the bottle.

Compatibility

HORIBA LAQUAtwin EC-11/EC-22 pocket meters; HORIBA LAQUAtwin Salt-11; HORIBA LAQUA EC200/EC210/EC220/EC1100/EC1500/EC2000 bench and handheld meters; HORIBA 9382-10D/9383-10D conductivity cells; any conductivity cell that accepts a 1,413 µS/cm (0.01 M KCl) standard.

Precautions

For calibration use only; do not ingest. Avoid contact with skin and eyes. Recap the bottle immediately after dispensing to prevent evaporation and CO₂ absorption which would change the conductivity value. Discard if the value drifts outside the stated accuracy.

FAQ

Is the HORIBA 1,413 uS/cm calibration solution certified and traceable?

HORIBA states that LAQUA standard solutions in dosing bottles are traceable to NIST standard reference materials, double-checked by an independent certified laboratory, and supplied with a certificate of analysis. The lot number on the bottle supports traceability.

What is the 1,413 uS/cm conductivity standard used for?

1,413 uS/cm (1.413 mS/cm) is the common mid-range conductivity standard for general water analysis, used for single-point calibration or as a check point for samples in the hundreds to few thousand uS/cm.

How long does the 1,413 uS/cm solution last once the bottle is opened?

HORIBA gives a 2 year sealed shelf life, with the expiry date on the label. The dosing bottle lets little air in, so usable life after opening is extended. Carbon dioxide in air can contaminate conductivity standards, so recap straight away and never pour used solution back.

Does the 1,413 uS/cm value change with temperature?

Yes, conductivity changes with temperature, so the nominal value is only valid at 25 C. The bottle carries a temperature table on its back label. Use that table, or a meter with temperature compensation, when the standard is not at 25 C.

Can I use this 500 ml standard with LAQUAtwin and bench meters?

It suits any meter or cell that accepts a 1,413 uS/cm standard, including HORIBA LAQUA conductivity meters. The 500 ml dosing bottle fills a separate calibration chamber, so used solution is discarded and never returns to the bottle. Rinse the cell with deionised water after use.