SCT-ORP-MAXI-HR ORP maxi controller, HR series (SCT-108.005.18)
Key features
- Microprocessor-based online ORP controller for stable, accurate readings
- Large, clear LCD display
- Isolated 4-20 mA current output
- Low power consumption and low internal heat
- Built for continuous in-line measurement in harsh environmental conditions
- Supplied with a ORP electrode with standard 10 m cable
Overview
The SCT-ORP-MAXI-HR is a panel-mount instrument for industrial online ORP (redox) measurement and control. It has a simple, compact design, a large clear LCD and an insulated 4-20 mA output, and is supplied with an ORP electrode on a standard 10 m cable for in-line measurement.
Specifications
| Product no | SCT-108.005.18 |
|---|---|
| Model no | SCT-ORP-MAXI-HR |
| Parameter | ORP (oxidation reduction potential) |
| Output current | Isolated 4~20 mA |
| Display | Large LCD |
| Sensor cable | 10 m |
| Installation method | Panel-mounted |
| Weight | 1.5 kg |
Applications
Online ORP measurement and control in water treatment, disinfection and RO systems, swimming-pool and cooling-water applications.
Setup guide
- Mount the controller in the panel cut-out and fix it with the clamp.
- Wire the power supply and the 4-20 mA output to your PLC, recorder or dosing system.
- Install the sensor at the measurement point and route its 10 m cable to the controller.
- Calibrate with the appropriate standard before first use.
- Set the control limits and verify the output responds to out-of-range readings.
In the box
- SCT-ORP-MAXI-HR controller
- ORP electrode with standard 10 m cable
- Fixation clamp
- Instruction manual
Precautions
Install and wire by qualified personnel only, with the power isolated. Keep the sensor wet and clean; calibrate regularly for accurate readings.
Documents
FAQ
What is the HR series, and how does the SCT-ORP-MAXI-HR differ from the SCT-ORP-MAXI?
The SCT-ORP-MAXI-HR sits in the High Range Maxi group with a large LCD, isolated 4-20 mA output and a 10 m electrode cable. No range, accuracy or relay difference from the standard SCT-ORP-MAXI is published, so confirm the details on the datasheet if you need them for a specification.
Where is the SCT-ORP-MAXI-HR used?
It is intended for online ORP (redox) measurement and control in water treatment, disinfection and RO systems, and swimming pool and cooling-water applications. The reading is a process indicator for the overall oxidizing or reducing condition of the water rather than a measure of a single chemical.
Can ORP on the SCT-ORP-MAXI-HR be read as a chlorine concentration?
No. ORP responds to all redox-active species together, so mV is not a concentration. A practical approach is to find the mV value that corresponds to acceptable conditions by comparing with a chemical test such as DPD on your own water, then use that value as the control setpoint.
How do I check and clean the SCT-ORP-MAXI-HR electrode?
Check response in an ORP standard such as Zobell-type solution, whose nominal value depends on temperature and reference type, and compare with the label. Clean by soaking 10 to 15 minutes in water with a little dishwashing liquid and wiping the platinum with a cotton swab, then rinse. Never store the electrode dry.