Scichemtech · scichemtech.ae · +971 50 391 6126 · sales@sctme.ae
PharmaSafe 2~8°C Pharmacy Refrigerator, 638 L, Single Glass Door | Each (MPR-656)
Key features
- 638 L upright pharmacy refrigerator holding 2~8°C for vaccines, medicines and biological samples
- Forced-air cooling, dual sensors and auto defrost for even, accurate temperature
- TC-100 microprocessor controller with LED display to 0.1°C
- Built-in data memory with USB download and 24-hour max/min check
- Alarms for high/low temperature, door open, power failure, sensor error and low battery, plus remote alarm contact
- 3-layer glass door with lock, LED lighting and 5 adjustable shelves
Overview
The Antech Scientific MPR-656 is a 638 L upright pharmacy refrigerator from the PharmaSafe series, made for hospitals, pharmacies and laboratories that need accurate 2~8°C storage for vaccines, medicines and biological material. Forced-air cooling and a dual-sensor system (separate control and display sensors) keep the temperature even, and the TC-100 controller shows the chamber temperature to 0.1°C. Readings are stored in the unit and can be downloaded over USB, and a remote alarm contact connects it to a building alarm system. The cabinet uses natural R290 refrigerant and CFC-free polyurethane insulation, and PharmaSafe refrigerators are CE certified.
Specifications
| Model | MPR-656 (PharmaSafe series) |
|---|---|
| Brand | Antech Scientific |
| Type | Upright pharmacy refrigerator, single glass door |
| Temperature range | 2~8°C |
| Climate class | N |
| Capacity | 638 L |
| Cooling | Forced air |
| Defrost | Automatic |
| Refrigerant | R290 (natural) |
| Controller | TC-100 microprocessor, dual sensors |
| Display | LED digital, 0.1°C resolution |
| Data | Built-in memory, USB port, 24-hour max/min check |
| Cloud monitoring (Wi-Fi) | Optional |
| Alarms | High/low temperature, door open, power failure, sensor error, low battery (visible and audible) |
| Remote alarm contact | Yes |
| Door | 1, 3-layer glass, lock with key |
| Interior light | LED |
| Test access port | Ø19 mm x 1 |
| Shelves | 5 adjustable |
| Castors | Yes |
| Exterior / interior | Coated steel / coated steel |
| Insulation | Polyurethane, 60 mm |
| Internal dimensions (W x D x H) | 660 x 650 x 1400 mm |
| External dimensions (W x D x H) | 780 x 840 x 1965 mm |
| Packing dimensions (W x D x H) | 840 x 870 x 2150 mm |
| Net / gross weight | 144 / 201 kg |
| Power supply | 220 V 50 Hz, 220 V 60 Hz or 120 V 60 Hz |
| Rated power | 260 W / 260 W / 250 W |
| Rated current | 1.5 A / 1.5 A / 2.6 A |
| Certification | CE (LVD, TÜV) |
Applications
Used in hospitals, pharmacies, blood banks, vaccine storage facilities, and research labs for storage of vaccines, biologics, blood products, pharmaceuticals, and temperature-sensitive reagents at 2-8°C. The 638 L capacity supports medium-to-large pharmaceutical operations.
Setup guide
- Place unit on level floor with 10 cm rear clearance; allow 4 hours for refrigerant to settle.
- Connect power; set target temperature to 4°C via control panel.
- Allow 24 hours for temperature stabilization.
- Conduct temperature mapping (empty vs loaded); adjust if needed.
- Load samples (max 70% capacity); verify USB logging and remote alarm contact via test.
Compatibility
Includes: refrigerator, 5 adjustable shelves, door keys, user manual. Optional: Wi-Fi cloud temperature monitoring; external temperature data logger.
Precautions
Do not freeze samples — set temperature above 2°C with margin. Connect to backup power (UPS) for critical pharmaceuticals. Do not block internal air vents with samples. Allow 24-hour stabilization after installation before loading. Validate temperature mapping before loading critical samples.
Documents
FAQ
What temperature range is the MPR-656 refrigerator listed for?
It is listed as a medical and pharmaceutical refrigerator for +2 to +8 C storage. For refrigerated vaccines, CDC guidance sets thermostats at the factory-set or midpoint temperature, for example 5 C, which leaves margin on both sides of the 2 to 8 C range.
How should vaccines be arranged in the MPR-656?
Leave space between boxes, do not block air vents, and keep vaccines 2 to 3 inches (5 to 8 cm) from the walls, cooling vents and door. Do not store them in the door or in drawers, because temperatures there are less stable.
How do I monitor temperature in the MPR-656?
Use a calibrated digital data logger with a buffered probe, placed in the centre of the unit with the vaccines around it. CDC guidance asks for a current certificate of calibration testing, with recalibration every 2 to 3 years or as the manufacturer recommends.
What happens in a power failure with the MPR-656?
Keep the door closed during an outage and move products to a backup unit or a qualified cold-chain container if the temperature leaves the 2 to 8 C range. For critical stock, connect a UPS or generator. Check the manual for the unit's own power-failure alarm and battery behaviour.
Should the MPR-656 be mapped before loading stock?
Yes. After installation, let the unit stabilise, then check temperature empty and loaded with calibrated loggers in several locations. This confirms that every shelf stays within 2 to 8 C before critical products are stored.