Scichemtech
Categories33
Region · LanguageKZ · English
United Arab Emirates

English

Saudi Arabia

English

Qatar

English

Oman

English

Kuwait

English

Bahrain

English

Middle East & North Africa

English

Türkiye

TürkçeEnglish

Kazakhstan

РусскийҚазақшаEnglish

Uzbekistan

O'zbekchaРусскийEnglish

+971 50 391 6126WhatsAppsales@sctme.ae
84 uS/cm Calibration Solution, 500 ml | 500ml/ Bottle (1300045632)Price on request
SKU: 1300045632Brand: HORIBA

84 uS/cm Calibration Solution, 500 ml | 500ml/ Bottle (1300045632)

Key features

  • NIST-traceable 84 µS/cm conductivity calibration solution, ±1% accuracy
  • Supplied in a 500 ml dosing bottle for convenient, drip-free dispensing
  • Comes with a certificate of analysis for full metrological traceability
  • Ideal low-conductivity calibration point for high-purity water and low-ionic-strength samples
  • Compatible with HORIBA LAQUA conductivity meters and other conductivity cells that accept an 84 µS/cm standard
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

HORIBA 84 µS/cm (±1% at 25°C) Conductivity Calibration Solution is a NIST-traceable low-conductivity standard supplied in a 500 ml dosing bottle with certificate of analysis. It is used to calibrate conductivity cells in the low range (typical of drinking water, river water and lightly contaminated process water).

Specifications

Article number1300045632
ProductConductivity Standard Solution 500-EC-84
Nominal value84 µS/cm at 25°C
Accuracy±1%
CompositionKCl aqueous solution
Volume500 ml
PackagingDosing bottle with dropper cap
TraceabilityNIST-traceable, supplied with certificate
Temperature reference25 °C
Shelf life2 years sealed, expiry date on bottle label
Storage5-30 °C, tightly closed, away from direct sunlight
BrandHORIBA Advanced Techno, Co., Ltd.

Applications

Used as a low-range conductivity calibration standard for HORIBA conductivity cells and electrodes, especially when measuring drinking water, river water, aquarium water, low-TDS process water, or any sample with conductivity below ~200 µS/cm. Particularly important for establishing the low-range slope of multi-point calibrations.

Setup guide

  1. Dispense a small amount of fresh 84 µS/cm standard into a clean, dry beaker .
  2. Immerse the conductivity cell and start calibration.
  3. Wait for the reading to stabilise and confirm the 84 µS/cm calibration point.
  4. Rinse the cell thoroughly with DI water before measuring samples or moving to the next standard.
  5. Discard used standard — never return it to the bottle.

Compatibility

HORIBA LAQUA EC200/EC210/EC220/EC1100/EC1500/EC2000 bench and handheld meters; HORIBA 9382-10D/9383-10D conductivity cells; any conductivity cell that accepts an 84 µS/cm KCl standard.

Precautions

For calibration use only; do not ingest. Avoid contact with skin and eyes. Recap the bottle immediately after dispensing to prevent evaporation and CO₂ absorption which would change the conductivity value. Discard if the value drifts outside the stated accuracy.

FAQ

Is the HORIBA 84 uS/cm calibration solution certified and traceable?

HORIBA states that LAQUA standard solutions in dosing bottles are traceable to NIST standard reference materials, double-checked by an independent certified laboratory, and supplied with a certificate of analysis. The lot number on the bottle supports traceability.

What is the 84 uS/cm conductivity standard used for?

At 84 uS/cm it is a low-range point for pure and lightly mineralised water, used to calibrate or verify conductivity cells at the low end. It should match the range of your samples; low values are the most sensitive to contamination and air exposure.

How long does the 84 uS/cm solution last once the bottle is opened?

HORIBA gives a 2 year sealed shelf life, with the expiry date on the label. The dosing bottle lets little air in, so usable life after opening is extended. Carbon dioxide in air can contaminate conductivity standards, especially low values, so recap straight away and never pour used solution back.

Does the 84 uS/cm value change with temperature?

Yes, conductivity changes with temperature, so the nominal value is only valid at 25 C. The bottle carries a temperature table on its back label. Use that table, or a meter with temperature compensation, when the standard is not at 25 C.

Can I use this 500 ml standard with LAQUAtwin and bench meters?

It suits any meter or cell that accepts a 84 uS/cm standard, including HORIBA LAQUA conductivity meters. The 500 ml dosing bottle fills a separate calibration chamber, so used solution is discarded and never returns to the bottle. Rinse the cell with deionised water after use.