Scichemtech
Categories33
Region · LanguageKW · English
United Arab Emirates

English

Saudi Arabia

English

Qatar

English

Oman

English

Kuwait

English

Bahrain

English

Middle East & North Africa

English

Türkiye

TürkçeEnglish

Kazakhstan

РусскийҚазақшаEnglish

Uzbekistan

O'zbekchaРусскийEnglish

+971 50 391 6126WhatsAppsales@sctme.ae
LAQUAtwin F-11, Fluoride Pocket meter with plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper | Each (3200934412)Price on request
SKU: 3200934412Brand: HORIBA

LAQUAtwin F-11, Fluoride Pocket meter with plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper | Each (3200934412)

Key features

  • Only pocket meter that directly measures fluoride ion (F⁻) concentration from a single drop of sample (≥0.05 ml with sampling sheet B)
  • Extensive Measurement Range
  • Convenient Two-Point Auto Calibration
  • : Achieve accuracy with two-point calibration, as the meter automatically recognizes and calibrates 1 ppm and 10 ppm fluoride ion standard solutions included in the kit. Customize calibration using other standard solutions that are ten-fold apart in concentration.
  • Auto Stable & Auto Hold Measurement Modes
  • : Assisting users record stable readings, the meter displays smiley indicator and can freeze the reading.
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

LAQUAtwin F-11: The World’s First Pocket-Sized Fluoride Ion Meter

Specifications

ModelF-11
Measurement principleIon selective electrode
Measurement range0.1 to 990 ppm (mg/L)
Resolution0.1 ppm (0.1 to 9.9 ppm), 1 ppm (10 to 99 ppm), 10 ppm (100 to 990 ppm)
Accuracy± 2% of actual value
Calibration pointsUp to 2
Minimum sample volume0.3 mL (0.01 mL with sampling sheet B)
Temperature display range0 to 50.0 °C
Temperature resolution0.1 °C
FunctionsAutomatic standard recognition, Changeable Low and High calibration values, Temperature calibration, Multiplying compensation (0.01 to 9.90), Auto hold / Auto stable measurement modes, Automatic power off (30 mins.), Low battery indicator, Replaceable sensor
Waterproof ratingIP67 water / dust proof
DisplayCustom (monochrome) digital LCD with backlight
Operating temperature5 to 40.0 °C
Operating humidity≤ 85% relative humidity (no condensation)
Power2 × CR2032 batteries
Battery lifeApprox. 400 hrs. continuous use without backlight
MaterialsABS epoxy body / LaF3 crystal sensor
Dimensions164 × 29 × 20 mm (excluding projections)
WeightApprox. 50 g (excluding batteries)

Applications

Used for direct measurement of fluoride ion (F⁻) in drinking water, ground water, toothpaste, mouthwash, food and beverage samples, and industrial process water. Common applications include drinking-water fluoridation monitoring, environmental compliance, and laboratory teaching of ion-selective electrode measurement.

Setup guide

  1. Insert 2 × CR2032 batteries into the meter (battery compartment on the back).
  2. Remove the sensor cap and apply a few drops of the 1 ppm fluoride standard (514-F-1, with TISAB) onto the flat sensor; press the calibration key and wait for the meter to auto-recognise the standard.
  3. Rinse the sensor with DI water, then apply the 10 ppm fluoride standard (514-F-10, with TISAB) and repeat the calibration.
  4. Rinse again, then apply 0.05-0.3 ml of the sample (use sampling sheet B for 0.05 ml volumes).
  5. Wait for the auto-stable indicator and read the concentration in ppm.

Compatibility

HORIBA LAQUAtwin 4M Kit (1300083234); HORIBA fluoride standard solutions 514-F-1 (1 ppm) and 514-F-10 (10 ppm), 14 ml bottles; HORIBA TISAB solution 514-F-TISAB; HORIBA sampling sheet B (Y046); CR2032 batteries; HORIBA rinse bottle (60 ml).

Precautions

Handle the flat sensor carefully — do not scratch the ion-selective membrane with sharp or abrasive objects. Always rinse the sensor with DI water after measuring corrosive or high-ionic-strength samples. Replace the sensor cap when not in use to prevent dehydration of the membrane. Use only HORIBA-recommended standard solutions for calibration.

FAQ

How does the LAQUAtwin F-11 measure fluoride and what is the range?

The F-11 uses a replaceable lanthanum fluoride (LaF3) crystal ion-selective sensor. It reads 0.1 to 990 ppm (mg/L) with plus or minus 2 percent accuracy, from 0.3 mL of sample or less with a sampling sheet. Auto Stable and Auto Hold modes help you capture a steady reading.

Which standards and calibration does the F-11 use?

It auto-calibrates in two points using the supplied 1 ppm and 10 ppm fluoride standards. You can use other standards as long as they are ten-fold apart, and the low and high calibration values can be changed. The kit also includes TISAB solution, a 5 mL plastic beaker, a syringe and sampling sheets.

What is TISAB solution and why does the F-11 kit include it?

TISAB is a total ionic strength adjusting buffer, used in fluoride electrode methods so that standards and samples have the same ionic strength. HORIBA supplies 14 mL TISAB with the F-11 and lists 514-F-TISAB as an accessory. HORIBA's application note mixes 1 mL TISAB with 1 mL of each standard, and with the sample when Fe3+, Al3+, Si4+ or highly concentrated ions are present.

How do I replace the F-11 sensor and what is the replacement part?

HORIBA lists the S060-F fluoride sensor as the replacement for the F-11, a replaceable LaF3 crystal sensor. After replacing it, calibrate again with fresh standards. Rinse the sensor after use and keep the meter in its case.