Scichemtech · scichemtech.ae · +971 50 391 6126 · sales@sctme.ae
LAQUAtwin F-11, Fluoride Pocket meter with plastic carry-case, 14 ml buffer/standard solutions, 2 x CR2032 batteries, dropper | Each (3200934412)
Key features
- Only pocket meter that directly measures fluoride ion (F⁻) concentration from a single drop of sample (≥0.05 ml with sampling sheet B)
- Extensive Measurement Range
- Convenient Two-Point Auto Calibration
- : Achieve accuracy with two-point calibration, as the meter automatically recognizes and calibrates 1 ppm and 10 ppm fluoride ion standard solutions included in the kit. Customize calibration using other standard solutions that are ten-fold apart in concentration.
- Auto Stable & Auto Hold Measurement Modes
- : Assisting users record stable readings, the meter displays smiley indicator and can freeze the reading.
Overview
LAQUAtwin F-11: The World’s First Pocket-Sized Fluoride Ion Meter
Specifications
| Model | F-11 |
|---|---|
| Measurement principle | Ion selective electrode |
| Measurement range | 0.1 to 990 ppm (mg/L) |
| Resolution | 0.1 ppm (0.1 to 9.9 ppm), 1 ppm (10 to 99 ppm), 10 ppm (100 to 990 ppm) |
| Accuracy | ± 2% of actual value |
| Calibration points | Up to 2 |
| Minimum sample volume | 0.3 mL (0.01 mL with sampling sheet B) |
| Temperature display range | 0 to 50.0 °C |
| Temperature resolution | 0.1 °C |
| Functions | Automatic standard recognition, Changeable Low and High calibration values, Temperature calibration, Multiplying compensation (0.01 to 9.90), Auto hold / Auto stable measurement modes, Automatic power off (30 mins.), Low battery indicator, Replaceable sensor |
| Waterproof rating | IP67 water / dust proof |
| Display | Custom (monochrome) digital LCD with backlight |
| Operating temperature | 5 to 40.0 °C |
| Operating humidity | ≤ 85% relative humidity (no condensation) |
| Power | 2 × CR2032 batteries |
| Battery life | Approx. 400 hrs. continuous use without backlight |
| Materials | ABS epoxy body / LaF3 crystal sensor |
| Dimensions | 164 × 29 × 20 mm (excluding projections) |
| Weight | Approx. 50 g (excluding batteries) |
Applications
Used for direct measurement of fluoride ion (F⁻) in drinking water, ground water, toothpaste, mouthwash, food and beverage samples, and industrial process water. Common applications include drinking-water fluoridation monitoring, environmental compliance, and laboratory teaching of ion-selective electrode measurement.
Setup guide
- Insert 2 × CR2032 batteries into the meter (battery compartment on the back).
- Remove the sensor cap and apply a few drops of the 1 ppm fluoride standard (514-F-1, with TISAB) onto the flat sensor; press the calibration key and wait for the meter to auto-recognise the standard.
- Rinse the sensor with DI water, then apply the 10 ppm fluoride standard (514-F-10, with TISAB) and repeat the calibration.
- Rinse again, then apply 0.05-0.3 ml of the sample (use sampling sheet B for 0.05 ml volumes).
- Wait for the auto-stable indicator and read the concentration in ppm.
Compatibility
HORIBA LAQUAtwin 4M Kit (1300083234); HORIBA fluoride standard solutions 514-F-1 (1 ppm) and 514-F-10 (10 ppm), 14 ml bottles; HORIBA TISAB solution 514-F-TISAB; HORIBA sampling sheet B (Y046); CR2032 batteries; HORIBA rinse bottle (60 ml).
Precautions
Handle the flat sensor carefully — do not scratch the ion-selective membrane with sharp or abrasive objects. Always rinse the sensor with DI water after measuring corrosive or high-ionic-strength samples. Replace the sensor cap when not in use to prevent dehydration of the membrane. Use only HORIBA-recommended standard solutions for calibration.
FAQ
How does the LAQUAtwin F-11 measure fluoride and what is the range?
The F-11 uses a replaceable lanthanum fluoride (LaF3) crystal ion-selective sensor. It reads 0.1 to 990 ppm (mg/L) with plus or minus 2 percent accuracy, from 0.3 mL of sample or less with a sampling sheet. Auto Stable and Auto Hold modes help you capture a steady reading.
Which standards and calibration does the F-11 use?
It auto-calibrates in two points using the supplied 1 ppm and 10 ppm fluoride standards. You can use other standards as long as they are ten-fold apart, and the low and high calibration values can be changed. The kit also includes TISAB solution, a 5 mL plastic beaker, a syringe and sampling sheets.
What is TISAB solution and why does the F-11 kit include it?
TISAB is a total ionic strength adjusting buffer, used in fluoride electrode methods so that standards and samples have the same ionic strength. HORIBA supplies 14 mL TISAB with the F-11 and lists 514-F-TISAB as an accessory. HORIBA's application note mixes 1 mL TISAB with 1 mL of each standard, and with the sample when Fe3+, Al3+, Si4+ or highly concentrated ions are present.
How do I replace the F-11 sensor and what is the replacement part?
HORIBA lists the S060-F fluoride sensor as the replacement for the F-11, a replaceable LaF3 crystal sensor. After replacing it, calibrate again with fresh standards. Rinse the sensor after use and keep the meter in its case.