514-ORP-225 mV ORP Standard Solution (6 x 14ml bottles per pack) | Each (3200997084)Price on request
SKU: 3200997084Brand: HORIBA

514-ORP-225 mV ORP Standard Solution (6 x 14ml bottles per pack) | Each (3200997084)

Key features

  • HORIBA 514-ORP-225 225 mV ORP standard solution, supplied as 6 × 14 ml dropper bottles
  • ORP reference standard (Zobell's solution)
  • Used to verify or calibrate ORP electrodes and the LAQUAtwin ORP-11 pocket meter
  • Small-volume dropper bottles; recap after use and never return used solution to the bottle
  • Convenient 14 ml size — apply a few drops directly onto the LAQUAtwin flat sensor or immerse an ORP electrode
PricePrice on requestIn stock
WhatsApp

Request a quote

Overview

HORIBA 514-ORP-225 (article 3200997084) is a 225 mV ORP (oxidation-reduction potential) standard solution supplied as a pack of six 14 ml dropper bottles. It is used to verify or calibrate ORP electrodes and the LAQUAtwin ORP-11 pocket meter, ensuring the ORP reading is traceable to a known redox value at 25 °C.

Specifications

Article number3200997084
HORIBA model514-ORP-225
ParameterORP (Oxidation-Reduction Potential)
Nominal value225 mV at 25 °C
Pack6 × 14 ml dropper bottles
CompatibilityLAQUAtwin ORP-11; HORIBA 9301-10D / 9300-10D ORP electrodes; HORIBA 300-O-C sensor cartridge; HORIBA WQ-300 series
TraceabilityHORIBA quality-controlled formulation
Storage5-30 °C, tightly closed, away from direct sunlight
Shelf lifeSee bottle label (typically 12-24 months unopened)
BrandHORIBA Advanced Techno, Co., Ltd.

Applications

Used to verify or calibrate ORP electrodes and the LAQUAtwin ORP-11 pocket meter before measuring ORP in drinking water, wastewater, aquaculture, process water or environmental samples. The 225 mV value provides a single-point check of electrode response.

Setup guide

  1. Open one 14 ml bottle of 514-ORP-225 (225 mV) standard.
  2. Apply a few drops directly onto the LAQUAtwin ORP-11 flat sensor (or immerse the ORP electrode tip in a small beaker of the standard).
  3. Press the calibration key — the meter will read 225 mV; confirm to store the calibration.
  4. Rinse the sensor/electrode thoroughly with DI water.
  5. Proceed with sample measurement; discard the used standard — never return it to the bottle.

Compatibility

HORIBA LAQUAtwin ORP-11 pocket meter (article 6178); HORIBA 9301-10D ORP electrode; HORIBA 9300-10D ORP electrode; HORIBA 300-O-C sensor cartridge; HORIBA WQ-300 series multi-parameter sondes.

Precautions

For calibration use only; do not ingest. Avoid contact with skin and eyes. Recap each bottle immediately after dispensing to prevent evaporation and oxidation. Do not return used standard to the bottle. Dispose of expired standard according to local regulations.

FAQ

What is the 514-ORP-225 standard and what does the LAQUAtwin ORP-11 do with it?

514-ORP-225 is a 225 mV ORP standard (Zobell's solution) in 6 x 14 mL bottles, matching the standard supplied with the ORP-11. The ORP-11 recognises it and completes a one-point calibration. Custom values from minus 500 to plus 500 mV can also be set for other standards.

How do I calibrate the ORP-11 with the 225 mV standard?

Optionally rinse the sensor with a little standard first for better accuracy, then drop enough standard to cover the whole measuring part, close the light shield cover and press CAL. The meter calibrates at the temperature measured by the built-in sensor. Afterwards wash the sensor with pure water and gently dry it before measuring a sample.

How can I use the 225 mV standard to condition a dry ORP-11 sensor?

Before first use or after several days of disuse, place some drops of ORP standard on the measurement part, wait 5 minutes (the meter need not be on), then clean with pure water and calibrate. If readings are slow or poorly repeatable, gently polish the platinum electrode with the supplied abrasive swab.

What range and accuracy does the ORP-11 have?

The ORP-11 reads minus 1000 to plus 1000 mV with 1 mV resolution and repeatability of plus or minus 2 mV. It needs 0.3 mL (0.05 mL with sampling sheet), is rated IP67 and runs about 400 hours on two CR2032 cells with the backlight off.